DellTM PowerEdgeTM M1000e Fully Modular Blade Enclosure
Energy Efficiency That Can’t Be Beat
Dell blade servers deliver performance and efficiency without compromise. The PowerEdge M1000e with the M600performs up to 12% 1 better than the IBMBladeCenter H, delivers up to 25% 2 better performance/watt than both the HP BladeSystem c-Class 2 and consumes up to 19% 3 less power than HP BladeSystem c-Class, which can help customers to increase capacity and lower operating costs
Energy Efficiency That Can’t Be Beat
Dell blade servers deliver performance and efficiency without compromise. The PowerEdge M1000e with the M600performs up to 12% 1 better than the IBMBladeCenter H, delivers up to 25% 2 better performance/watt than both the HP BladeSystem c-Class 2 and consumes up to 19% 3 less power than HP BladeSystem c-Class, which can help customers to increase capacity and lower operating costs
Easy to Use, Powerful Management Tools
|
FlexAddress, The Simple Low Cost Way To Limit Downtime
Chassis Enclosure | |
Form Factor: 10U modular enclosure holds up to sixteen half-height blade servers 440.5mm (17.34") H x 447.5mm (17.62")W x 753.6mm (29.67")D Weight: Empty Chassis only – 98lbs (44.5kg) Chassis w/ all rear modules (IOMs, PSUs, CMCs, KVM) - 176lbs (79.8kg) Max Fully loaded w/ blades and rear modules - 394lbs (178.7kg) | |
Power Supplies | |
3 (non-redundant) or 6 (redundant) 2360 watt hot plug power supplies Based on Dell’s Energy Smart Technologies, the M1000e Power Supplies deliver greater levels of efficiency, even at very low levels of utilisation Redundant Power Supplies support 3+3 (AC redundancy), 3+1 (Power Supply Redundancy), or 3 + 0 (non-redundant) modes System supports new Dynamic Power Supply Engagement functionality, which (if enabled) puts lightly loaded power supplies into standby mode, driving up the utilisation and thus the efficiency on the active supplies Power Supplies Require 200+ volt AC input Dell offers a wide range of Power Distribution options for the M1000e with 20A, 30A, 60A single phase, or 30A three phase options | |
Cooling Fans | |
M1000e Chassis comes standard with 9 hot pluggable, redundant fan modules Based on Energy Smart Technologies, M1000e fans are a breakthrough in power and cooling efficiency. The fans deliver low power consumption, but also use next generation “low flow” technology to ensure the lowest possible amount of fresh air is consumed to cool the enclosure | |
Input Device | |
Front Control Panel with interactive Graphical LCD Supports initial configuration wizard Local server blade, enclosure, and module information and troubleshooting Two USB Keyboard/Mouse connections and one Video connection (requires the optional Avocent iKVM switch to enable these ports) for local front “crash cart” console connections that can be switched between blades | |
Enclosure I/O Modules | |
Up to six total I/O modules for three redundant fabrics, featuring Ethernet FlexIO Switches providing on demand stacking and uplink scalability. PowerConnectTM M6220 Ethernet Switch Includes 4 x fixed copper 10/100/1000Mb Ethernet uplinks plus 2 of the following optional modules: 2 x 24Gb Stacking Ports 2 x 10Gb Optical (XFP-SR/LR) uplinks 2 x 10Gb copper CX4 uplinks Standard Features include Layer 3 routing (OSPF, RIP, VRRP) IPv6 support Layer 2/3 QoS Access Control Lists Dell Ethernet Pass-Through Module Supports 16 x 10/100/1000Mb copper RJ45 connections Only Ethernet Pass-through module on the market that supports full range of 10/100/1000Mb operation Brocade® M4424 SAN I/O Module Access Gateway Mode or FC Switch Access Gateway Mode enables NPIV functionality on external ports which delivers enhanced fabric interoperability, simplified set up, and doesn’t consume an FC domain 12 or 24 port versions with 4 or 8 x FC 1/2/4Gb SFPs respectively 4Gb Fibre Channel Pass-Through Module 16 x FC 1/2/4Gb SFP ports | |
Management | |
System Management Dell OpenManageTM System Management Integration into 3rd party management solutions via Dell’s Preferred Partner Program Remote Management 1 (standard) or optional 2nd (redundant) Chassis Management Controller(s) (CMC) which provide: Single secure interface for inventory, configuration, monitoring, and alerting for the chassis and all components Real Time Power/Thermal Monitoring and Management Real Time System AC Power Consumption with reset-able peak and minimum values System level power limiting and slot based power prioritisation Manages Dynamic Power Engagement functionality Manages fan speed control Secure Web (SSL) and CLI (Telnet/SSH) interfaces Supports multiple levels of user roles and permissions, including integration into Microsoft Active Directory Services 2 x 10/100/1000Mb Ethernet ports + 1 serial port Provides single point of connection from management network to iDRAC on each of the blades and the management interfaces on the integrated I/O Modules 2nd Ethernet port supports daisy chaining of CMCs for improved cable management Optional Integrated Avocent® keyboard, video and mouse (iKVM) switch Enables USB and video port on front control panel iKVM module has 2 x USB, video, and Analog Console Interface (ACI) ports ARI port allows connectivity and seamless tiering via cat5 cables to Dell or Avocent KVM switches with Analog Rack Interface (ARI) ports. | |
Storage | |
External Storage Options: Dell/EMC fibre channel and/or iSCSI external storage |
wow its amazing technology.
ReplyDeletethanks for sharing us.
steel enclosures